Features
- Advanced sequential injection platform with reduced number of components, simple structure and easy troubleshooting.
- High-precision and stable injection pump with non-contact liquid quantification design, less water consumption for high-range dilution, and short dilution time.
- Ten-way valve flow path using laser micro-engraving technology, accurately controlling the size and positioning of the grooves, and using sapphire material for the valve core with ultra-high corrosion and wear resistance, long service life, and good stability.
- Integrated quartz digestion/colorimetric unit, not easily contaminated, and with high absorbance resolution.
- Imported cold light source, no preheating required, and with a life span of up to 100,000 hours.
- Innovative process and algorithm effectively eliminate turbidity interference, and the monitoring results are true and reliable.
- Optimized masking agent formula with strong anti-interference ability against impurity ions.
- Liquid reagents do not require low-temperature storage and can be stored at room temperature for more than 30 days.
- Power-off protection design to prevent data loss, and automatic recovery of working status when power is restored.
- Low comprehensive operation and maintenance cost for trace-level reagents and waste liquids.
- Intelligent fault alarm and automatic reset to avoid abnormal rotation of the instrument.
- Automatic verification and judgment function to meet the requirements of new standards.
- Customizable development of special functions and services to ensure user-friendly and humanized operation.
Technical parameters
Measurement range | 0~10/20/50/100 mg/L, and the measuring range can be customized according to customer requirements |
Repeatability | ≤2% |
Indication error | 0-10 measuring range, ±8% for 20% F.S, ±5% for 50% F.S, and ±3% for 80% F.S; |
10-100 measuring range, ±3% for 50% F.S; | |
24h low-concentration drift | ≤0.02mg/L |
24h high-concentration drift | ≤1% |
Quantitative lower limit | ≤0.15mg/L |
Resolution | 0.01mg/L |
Maintenance period | one month |
Measurement mode | immediate measurement/periodic measurement/cyclic measurement/external signal triggered measurement |
Standard solution verification | immediate verification/automatic verification/external signal triggered verification |
Instrument calibration | automatic/manual calibration, calibration cycle and time can be set |
Automatic cleaning | cleaning cycle can be set |
Data storage | 3 years of data storage |
Measurement period | 30 minutes |
Analog output | 2 channels of 4-20mA output |
Digital output | 1 channel of RS232/RS485 |
Power requirements | AC220±10%V, 50±10%Hz, 10A; power consumption less than 100W |
Operating temperature | (5~40)℃ |
Environmental humidity | ≤90%RH |
Dimensions | 700mm(H) x 500mm(W) x 400(D)mm without pre-processing system cabinet |
Weight | less than 30kg, without pre-processing system cabinet. |