AnalyDisin DPD Colorimetric Online Disinfectant (Residual chlorine, Total chlorine, Chlorine dioxide) Analyzer

nline Residual Chlorine Analyzer, DPD Colorimetric Disinfectant Water Quality Monitor
DPD colorimetric online residual chlorine analyzer for water disinfection monitoring
  • Online Residual Chlorine Analyzer, DPD Colorimetric Disinfectant Water Quality Monitor
    DPD colorimetric online residual chlorine analyzer for water disinfection monitoring

    Standard DPD Colorimetric Method: Complies with national standards, resists interference from other oxidants, and is not affected by pH, delivering stable and high-precision measurements for residual chlorine, total chlorine, chloramine, and chlorine dioxide.

  • Patented Fast Range Switching: Switch between high and low measuring ranges within 1 second. No need to replace the colorimetric module, adaptable to multiple water monitoring scenarios.
  • Dual-channel & Low Water Consumption: Supports two water sample measurements simultaneously; each measurement only consumes water for 30 seconds, saving water resources and reducing operating costs.
  • Low Maintenance & Humid-environment Adaptable: Built-in anti-fog heating design, self-cleaning function, reagent reminder, and wastewater separation function, greatly lowering manual maintenance and secondary pollution risk.
Products Categories

Typical Applications

  • Drinking Water Safety: Waterworks outlet tap water, end of water distribution network, secondary water supply, rural water improvement, direct drinking water, bottled water.
  • Industrial Process: Reverse osmosis feed water, circulating cooling water, boiler water, power plant warm discharge water, seawater desalination.
  • Medical and Disease Control: Monitoring and disinfection of medical wastewater and water sources after disasters.
  • Food Processing: Process water, CIP disinfection process water, bottle washing water.
  • Environmental Protection: Disinfection assessment of water sources, wastewater discharge.
  • Other Scenarios: Chlorination disinfection evaluation for swimming pool water, hot spring water, seawater aquaculture, laboratory comparison, etc.

Product Features

  • Adopts national standard DPD colorimetric method, which can mask interference from other oxidants and is not affected by pH value to achieve high-precision measurement.
  • Unique patented technology: it can switch between high and low ranges in 1 second, no need to replace the colorimetric module to meet monitoring requirements of multiple scenarios.
  • The colorimetric module is equipped with a built-in automatic heating function to prevent fogging of optical windows due to pre-cooling, suitable for humid environments.
  • It can monitor residual chlorine, total chlorine, chloramine, and chlorine dioxide in water, provide comprehensive judgment, guide disinfectant dosing, reduce the generation of by-products, save energy and cost, and ensure water safety.
  • Dual-channel design: one instrument can measure two water samples simultaneously and supports expansion of more sampling channels to reduce equipment investment cost.
  • Supports manual external sample injection and rapid detection, assisting temporary testing and laboratory comparison.
  • Adjustable measurement interval, only 30 seconds per measurement, no continuous water flow, greatly reducing water waste.
  • Visual reagent remaining volume, reminder for consumable replacement, and pipeline water shortage alarm to avoid abnormal measurement interruption.
  • Self-cleaning function with adjustable cleaning cycle, no manual maintenance required, convenient and labor-saving.
  • Wastewater / waste liquid separation function to reduce secondary pollution risk and cut waste liquid treatment cost.

Measuring Principle

  • Residual Chlorine: Under pH 6.2~6.5, free chlorine reacts directly with N, N‑Diethyl‑1,4‑phenylenediamine (DPD) to form red compound. The absorbance is measured at 525 nm, and the residual chlorine concentration is calculated via a working curve.
  • Total Chlorine: Under pH 6.2~6.5, free chlorine and combined chlorine (hypochlorite, chloramine, etc.) react with potassium iodide. The generated iodine molecules react with DPD for color development to form red compound. The absorbance is measured at 525 nm, and total chlorine concentration is calculated via working curve.
  • Chlorine Dioxide: Under pH 6.2~6.5, masking agent is added to eliminate interference from residual chlorine. Chlorine dioxide in water reacts with DPD to form red compound. The absorbance is measured at 525 nm, and absorbance is proportional to chlorine dioxide concentration. Chlorine dioxide concentration is calculated via working curve.
Parameter Performance Indicator
Measured Parameters Residual chlorine, total chlorine, chloramine, chlorine dioxide
Measuring Range 0–2 / 5 /10 mg/L
Indication Error Whichever is greater between ±3% or ±0.03 mg/L (0–2 mg/L)

Whichever is greater between ±5% or ±0.06 mg/L (0–5 mg/L)

Whichever is greater between ±10% or ±0.2 mg/L (0–10 mg/L)

Repeatability ≤3%
Limit of Detection ≤0.03 mg/L
Resolution 0.01 mg/L
24h Zero Drift ≤0.03 mg/L
pH Range 6.5–8.5, customized for special working conditions
online residual chlorine total chlorine analyzer, DPD method water quality monitoring instrument
online residual chlorine/total chlorine analyzer adopts DPD colorimetric method, for continuous water quality monitoring of residual chlorine, total chlorine and chloramine.
Technical indicators of AnalyDisin DPD online disinfectant analyzer
Technical data sheet of AnalyDisin DPD online disinfectant analyzer, including measuring range, accuracy, repeatability, detection limit and pH working range.

Get A Free Quote Now

if you have any questions please do not hesitate to contatct with us.

Related Products

Scroll to Top

Get A Free Quote Now!

Contact Form Demo (#4)